The laser gas analyzer is based on Tunable Diode Laser Absorption Spectroscopy (TDLAS), which uses the narrow line width and tunable characteristics of semiconductor lasers to analyze individual absorption lines of gas molecules. The laser frequency is modulated by modulating the working current of the semiconductor laser, so that when the laser beam of a specific wavelength emitted by the semiconductor laser passes through the measuring pipeline, it is frequency-selectively absorbed by the measured gas, and the laser intensity is attenuated. The lock-in amplifier is used to photoelectricity at the receiving end. The optical signal detected by the detector is demodulated, and combined with the Beer-Lambert relationship between the gas concentration and the laser absorption spectrum, the concentration of the measured gas is obtained.
Model | Configuration | Measurements | Measurement Range | Accuracy | Measurement Purpose |
![]() |
Single Gas |
O2 *Ready Solution |
O2: 0-1% / 0-2% / 0-5% / 0-10% /0-21% / 0-25% /0-50% * Other ranges available on request |
1% |
·Safety monitoring ·Explosion prevention ·Control combustion efficiency ·Process control optimization ·Gas recycle ·Methane emission |
CO *Ready Solution |
CO: 0-1000ppm/ 0-10000ppm / 0-3%/ 0-10% /0-30% /0-60% / 0-100% * Other ranges available on request |
1% | |||
CH4 *Ready Solution |
CH4: 0-1000ppm /0-5000ppm / 0-1% / 0-10%/ 0-20% * Other ranges available on request |
1% | |||
NH3 *Available on Request |
NH3: 0-20ppm * Other ranges available on request |
1% | ·DeNOx ammonia slip | ||
Dual Gas |
CO & CO2 *Ready Solution |
CO: 0-60% + CO2:0-20%; CO:0-100% + CO2:0-100% * Other ranges available on request |
1% |
·Control combustion efficiency ·Process control to optimization ·Gas recycle |
|
CO & CH4 *Available on Request |
CO: 0-1% + CH4: 0-4% * Other ranges available on request |
1% |
·Safety monitoring ·Explosion prevention ·Control combustion efficiency ·Process control & optimization ·Gas recycle ·Methane emission |
Model | Configuration | Measurements | Measurement Range | Accuracy | Measurement Purpose |
![]() |
Single Gas |
NH3 *Ready Solution |
0-20ppm up to 0-9999ppm * Other ranges available on request |
2% |
SCR or SNCR denitrification device NH3 gas slip emission monitoring and process monitoring. |
O2, CO, CH4, H2O, CO2, H2S, C2H2, *Available on Request |
O2: 0-1% up to 0-100% CO: 0-1000ppm up to 0-100% CH4: 0-1000ppm up to 0-20% H2S: 0-10ppm up to 0-5% H2O: 0-10ppm up to 0-5000 ppm CO2: 0-10ppm up to 0-5% C2H2: 0-10ppm up to 0-5000 ppm * Other ranges available on request |
2% |
· Safety control ·Process Cotrol ·Inertization |