| Detecting Principle | NDIR (non-dispersive infrared) technology | ||||||
| Measurement | HC (n-Hexane) | CO | CO2 | ||||
| Range (vol) | 0-20000 (×10-6) | 0-15% | 0-20% | ||||
| Resolution (vol) | 1×10-6 | 0.00% | 0.01% | ||||
| Range (vol) | 0-2000 | 2001-5000 | 5001-20000 | 0-10% | 10.01%-15% | 0-16% | 16.01%-20% |
| (×10-6) | (×10-6) | (×10-6) | |||||
| Abs. Error | ±10 (×10-6) | ±0.03% | ±0.4% | ||||
| Rel. Error | ±5% | ±5% | ±10% | ±3% | ±5% | ±4% | ±5% |
| Response Time (T90) | ≤4s | ||||||
| Gas Flow | 0.7-1.2L/min | ||||||
| Warm-up Time | 1 minute usable, 3 minutes to full performance | ||||||
| Power Supply | 12V / 0.15A | ||||||
| Power Consumption | 2W | ||||||
| Ambient Temperature | (5~45) °C | ||||||
| Relative Humidity | 0~90% RH (No condense water) | ||||||
| Atmospheric Pressure | (75~110) kPa | ||||||
| Communication | RS232 | ||||||
You can contact Cubic Instruments by telephone or email, or you can submit an online Request for Quotation Form.
For Sales: sales@gasanalyzer.com.cn
For Administration: info@gasanalyzer.com.cn